The mobile, all-around capabilities of the Fischer DMP family make them versatile enough for use in a wide range of applications. The flexible devices are the perfect solution for tactile and non-destructive coating thickness measurement of ferrous and non-ferrous base materials. For this, we have just the right model choices for your needs: ISOSCOPE®, DELTASCOPE® or DUALSCOPE®.
- Universal instrument series for tactile coating thickness measurement thanks to an incredibly wide probe portfolio
- Measured value memory: 250,000 measured values in 2,500 batches (DMP30/40) or 10,000 measured values in 1 batch (DMP10/20)
- Robust aluminum housing with IP64 protection, Gorilla Glass and soft bumpers
- Exchangeable Li-Ion battery for > 24 h operating time
- Easy data transfer via USB-C and Bluetooth
- Live feedback via light, sound and vibration for limit monitoring
- Cal Check function to verify your currently used calibration
- Digital and analog probes available for a wide range of applications, with the F-adapter you still have access to the entire Fischer probe portfolio
- Available with the new Tactile Suite software

Most powerful software: Get Tactile Suite, your efficient software solution with a new design, innovative user guidance and versatile functions for your evaluation and reporting.
Instantly recognized and synchronized: With the automatic and reliable device recognition, your probes and devices are recognized directly and your measurement data is transferred and stored easily and immediately.
Direct export to Excel: Transfer your measurement data in real time - or after measuring directly to Excel or other file formats - easily and conveniently via USB-C or Bluetooth.
Create data reports easily: Easily create customized reports and measurement logs. You can use our templates for this or adapt them according to your needs.
Download datasheet: DMP Series Tactile Measurement Devices
Download brochure: Tactile Measurement Devices: Contact Thickness Measurement and Materials Testing
ISOSCOPE®: Measurement of electrically non-conductive layers on non-magnetizable, electrically conductive base materials.


Application examples:
NC/NF: Paint, varnish or plastic on aluminum, copper or brass
NC/NF: Anodized coatings on aluminum
Measurement method:
Amplitude sensitive eddy current method
Discover the new benchmark! With the new ISOSCOPE® you increase the efficiency in measuring electrically insulating coatings on non-magnetizable, electrically conductive metals with the amplitude-sensitive eddy current method.
DELTASCOPE®: Measurement of non-magnetizable layers on magnetizable base materials.


Application examples:
NC/Fe: Paint, varnish or plastic on steel or iron
NF/Fe: Zinc, chrome or copper on steel or iron
Measurement method:
Magnetic inductive measuring method
Put an exclamation mark on it! DELTASCOPE® optimizes the measurement of non-magnetizable coatings on magnetizable base materials using magnetic-inductive measurement.
DUALSCOPE®: Measurement of electrically non-conductive layers on non-magnetizable, electrically conductive base materials and measurement of non-magnetizable layers on magnetizable base materials.


Application examples:
NC/NF: Paint, varnish, plastic on aluminum, copper, brass
NC/NF: Anodized coatings on aluminum
NC/Fe: Paint, varnish or plastic on steel or iron
NF/Fe: Zinc, chrome or copper on steel or iron:
Measurement method:
Amplitude-sensitive eddy current method and magnetic inductive measurement method
Take advantage of the flexibility! With the new DUALSCOPE® you can measure non-magnetizable or electrically non-conductive coatings on magnetizable or non-magnetizable, electrically conductive base materials with the eddy current or magnetic inductive measuring method.
| DUALSCOPE® |
DELTASCOPE® |
ISOSCOPE® |
|||||||
| Measurement of non-magnetizable or electrically non-conductive coatings on magnetizable or non-magnetizable, electrically conductive base materials | Measurement of non-magnetizable coatings on magnetizable base materials. | Measurement of electrically insulating coatings on non-magnetizable, electrically conductive metals. | |||||||
| Base material | Non-ferrous metal (NF) and steel or iron (FE) | Steel or iron (FE) | Non-ferrous metal (NF) | ||||||
| Application examples |
|
|
|
||||||
| Measuring method | Amplitude sensitive eddy current method AND Magnetic inductive measuring method | Magnetic inductive measuring method | Amplitude sensitive eddy current method | ||||||
| DMP 20 "Entry-level model" |
DUALSCOPE® DMP 40 "Comfort model" |
DMP 10 "Entry-level model" |
DMP 30 "Comfort model" |
DMP 10 "Entry-level model" |
DMP 30 "Comfort model" |
||||
| Measured value memory | ≤ 10,000 | ≤ 250,000 | ≤ 10,000 | ≤ 250,000 | ≤ 10,000 | ≤ 250,000 | |||
| Number of measurement tasks | 1 | ≤ 2,500 | 1 | ≤ 2,500 | 1 | ≤ 2,500 | |||
| Communication | USB-C | USB-C and Bluetooth | USB-C | USB-C and Bluetooth | USB-C | USB-C and Bluetooth | |||
| Limit monitoring | Light and sound | Light, sound and vibration | Light and sound | Light, sound and vibration | Light and sound | Light, sound and vibration | |||
| Standards | DIN EN ISO 2178, DIN EN ISO 2360, ASTM D7091, ASTM 4471 | DIN EN ISO 2178, ASTM D7091, ASTM 4471 | DIN EN ISO 2360, ASTM D7091, ASTM 4471 | ||||||