With Infleqtion's cryogenic ion trap housings, you'll have everything you need to take your ion trapping experiments to the next level! The cryogenic ion trap is designed with self-contained housings and offers a high-optical UHV environment for trapping ions with long trap lifetimes.

The trap surface is meticulously ion milled before assembly into an UHV-baked chamber, ensuring an ultra-clean surface free from impurities. The C-cut sapphire window material provides you can expect a low birefringence and high UV transparency for crystal clear views of your ion trapping experiments. Originally designed to house a Sandia HOA trap, the package is also compatible with the Peregrine and Phoenix ion traps.

Features

  • Compact UHV cell
  • Titanium body
  • AR-coated C-cut sapphire windows
  • 2 through axes at a 45-degree angle .12-.65 NA optical access
  • < 3 x 10^(-11) Torr vacuum pressure
  • HOA or Peregrine trap compatible
  • Adaptable to many chip traps
  • Yb and Ba targets available

Customization Options

  • Custom atom source
  • Custom window coatings
  • Adapt to your trap
  • AR coating on windows

Download datasheet here. 

Related Research:

An optically heated atomic source for compact ion trap vacuum systems

We present a design for an atomic oven suitable for loading ion traps, which is operated via optical heating with a continuous-wave multimode diode laser. The absence of the low-resistance electrical connections necessary for Joule heating allows the oven to be extremely well thermally isolated from the rest of the vacuum system. Extrapolating from high-flux measurements of an oven filled with calcium, we calculate that a target region number density of 100 cm−3, suitable for rapid ion loading, will be produced with 175(10) mW of heating laser power, limited by radiative losses. With simple feedforward to the laser power, the turn-on time for the oven is 15 s. Our measurements indicate that an oven volume 1000 times smaller could still hold enough source metal for decades of continuous operation.

Gao, W. J. Hughes, D. M. Lucas, T. G. Ballance, J. F. Goodwin; An optically heated atomic source for compact ion trap vacuum systems. Rev Sci Instrum 1 March 2021; 92 (3): 033205. https://doi.org/10.1063/5.0038162

Vacuum characterization of a compact room-temperature trapped ion system

We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2cm3⁠, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011Torr⁠, which is sufficient for the majority of current trapped ion experiments.

Yuhi Aikyo, Geert Vrijsen, Thomas W. Noel, Alexander Kato, Megan K. Ivory, Jungsang Kim; Vacuum characterization of a compact room-temperature trapped ion system. Appl. Phys. Lett. 7 December 2020; 117 (23): 234002. https://doi.org/10.1063/5.0029236

A short response time atomic source for trapped ion experiments

Ion traps are often loaded from atomic beams produced by resistively heated ovens. We demonstrate an atomic oven which has been designed for fast control of the atomic flux density and reproducible construction. We study the limiting time constants of the system and, in tests with 40Ca, show that we can reach the desired level of flux in 12 s, with no overshoot. Our results indicate that it may be possible to achieve an even faster response by applying an appropriate one-off heat treatment to the oven before it is used.

G. Ballance, J. F. Goodwin, B. Nichol, L. J. Stephenson, C. J. Ballance, D. M. Lucas; A short response time atomic source for trapped ion experiments. Rev Sci Instrum 1 May 2018; 89 (5): 053102. https://doi.org/10.1063/1.5025713