Ocean Optics DH-2000-CAL Deuterium Tungsten Halogen Calibration Standard |
|
The DH-2000-CAL Deuterium Tungsten Halogen Calibration Standard is a UV-NIR light source used to calibrate the absolute spectral response of a radiometric system. With the DH-2000-CAL and SpectraSuite Software, you can determine known absolute intensity values at wavelengths from 220-1050 nm. The DH-2000-CAL is specifically calibrated for use with optical fibres or a cosine corrector; the calibration data includes absolute intensities for wavelengths between 220-1050 nm at the fiber entrance port for both a bare fiber and a CC-3-UV Cosine Corrector.
Features -
UV-NIR Calibration Source. For use in performing fast, radiometric calibrations from 220-1050 nm -
NIST-traceable Calibration from 220-1050 nm. Provides absolute spectral intensity in µW/cm2/nm at the fiber port -
Calibration Certificate. Calibration data is provided in paper and electronic formats for use with SpectraSuite Software Included with the Lamp The DH-2000-CAL comes with the CC-3-UV Cosine Corrector. Also included is a calibration certificate and a diskette with a data file for use with our SpectraSuite Software. Other Calibration Services The DH-2000-CAL typically provides about 50 hours of operation before recalibration is necessary. We recalibrate these lamps in-house. Also, by using our SPEC-CAL-UV in-house calibration service, it is possible to have your UV spectrometer radiometrically calibrated without purchasing a DH-2000-CAL. The calibration is good for about one year, provided the optical fiber is not removed from the setup, as the system is calibrated specifically for use with a fiber. User's Tip Radiometric Calibration Sources are not illumination sources for spectroscopic measurements. For illumination, use the DH-2000. DH-2000-CAL Spectral Output  These spectral output graphs were taken separately for the deuterium (200-400 nm) and the tungsten halogen bulbs (400-1100 nm) to avoid a sharp line spectrum >400 nm in the deuterium trace. DH-2000-CAL Specifications | Dimensions: | 150 mm x 135 mm x 319 mm | | Weight: | 6 kg | | Power consumption: | 25 W (deuterium); 20 W (tungsten halogen) | | Calibrated range: | 220-1050 nm | | Calibration accuracy: | +/-5% | | Calibration valid for: | 50 hours | | Lamp current: | Operating 85 V/0.3A | | Lamp voltage: | 350 V | | Power requirements: | 85-264 V 50/60 Hz | | Current voltage drift: | <0.01% per hour | | Current voltage stability: | <5 x 10-6 peak-to-peak (0.1-10.0 Hz) | | Humidity: | 5-95% without condensation at 40 °C | | Operating temperature: | 5 °C - 35 °C | | Total power: | 100 W | | Power consumption: | 190 W maximum | | Warm-up time: | 40 minutes (deuterium); 20 minutes (tungsten halogen) | | Markings: | CE; VDI/VDE 0160; EN 61010 | |