Ames Photonics Garry 3000SD/3648 Series CCD Linear Gated Array Detector

Garry 3000SD/3648 series

Key Features

  • Integration time range: 10 us - 30 s
  • Fast, on CCD, electronic shutter capability
  • High resolution: 7 micron wide pixels on 7 micron centers
  • 200 micron high pixels
  • 3000 and 3600 pixel linear arrays
  • Advanced software options
  • Spectral range: 200-1100nm
  • Full PC control via external USB or PCI data acquisition modules
  • Stand Alone control via D7259 OEM control card for output to an oscilloscope
  • External trigger input and synch output at start of integration for synchronization to pulsed sources

The linear CCDs used in the GARRY SD series detector heads have a built-in electronic shutter facility. This allows these detectors to achieve accurate integration times down to 10 microseconds without external shutters.

The detectors can be controlled via a PC with either external USB or PCI interface modules and one of our software packages. Multiple detectors can be controlled enabling simultaneous acquisition with the SAM USB interfaces.

In Stand Alone operation the detector generates an analog output to an oscilloscope or external data acquisition device. This is accomplished with the optional D7259 OEM card, standalone interface board, that provides power to the detector head and allows selection of integration time between 10 us and 10s via two rotary switches.

Operation modes and synchronization capabilities

The detector heads can operate in two trigger modes, selected via the Trigger Mode switch on the back of the detector, regardless of interface:

  • Internal/self trigger mode
  • External trigger mode

Choosing between 3000 and 3648 element CCD

The main physical difference between the arrays is that the 3648 element array is 4.5mm longer. In some spectroscopic applications this may have an advantage. The 3000 element CCD is otherwise superior in all significant parameters and is compatible with TCDC technology, which allows correction for dark signal without having to first measure it. With the 3648 element CCD, if the dark signal is to be subtracted, then it should be measured just before the measurement cycle. This usually implies that there must be a shutter in the system or a means to block out all light from reaching the detector.

These dark signal considerations are however only relevant for long integration times, when there is time for enough dark signal to accumulate in the CCD during measurement. For integration times below 10ms there is usually no need to correct for dark signal.



You are here: Home Cameras Linear Array Ames Photonics Garry 3000SD/3648 Series CCD Linear Gated Array Detector